---
title: "Lighting installation in Putney | 5.0 Star · NICEIC"
description: "Lighting installation in Putney connects new lamps, dimmers and outdoor lamps, then tests the circuit before power returns to those lamps."
canonical: "https://belloelectricsltd.co.uk/electrician-putney/lighting-installation"
---

# Lighting installation in Putney

> Lighting installation in Putney connects new lamps, dimmers and outdoor lamps, then tests the circuit before power returns to those lamps.

Bello Electrics Ltd fits lighting installation in Putney, joining each new lamp to a tested circuit so the switch or dimmer operates the lamp.


## What does the lighting price pay for?

The price pays for one light point, one lamp joined to the lighting cable. Another lamp changes the price. A control that fades the lamp changes the price. A plate chosen for its look changes the price. A cover that has to carry the cable in sight changes the price. Plaster repairs and a lighting circuit that has already failed sit outside the price.

From £95. [Prices for lighting installation](https://belloelectricsltd.co.uk/services/lighting-installation#prices)
- One light point includes opening the lighting breaker, fixing a single lamp and landing live, neutral and earth.
- Every lamp past that one is priced as another light point.
- A dimmer module, the part that sets brightness, moves the price. So does a linear LED profile, a slim lamp level with the surface, a decorative plate, trunking or conduit. Trunking is a squared cover. Conduit is a tube.
- Filling plaster and painting the ceiling are separate. Supplying a chandelier is separate. New cable on a lighting circuit that has already failed is separate.

## Lighting installation across Putney

We serve Putney from our base in Mitcham.
- Putney High Street
- Putney Heath
- West Hill
- SW15

## What happens on the day

Lighting installation in Putney runs from the mark on the ceiling to the working control. We mark each lamp. We open its breaker and leave it open. We draw the cable and join the lamp. We fit the control. We take the readings, then close the breaker.

### Which lamps are fitted?

We fit a pendant that hangs, a downlight sunk into the ceiling, a wall lamp, a long LED lamp set flush, and a lamp outside. LED means the lamp makes light from a small chip and draws little power. A pendant drops from a ceiling rose, the base screwed to the ceiling. A downlight shines down from a hole cut for it. The long LED lamp is a linear profile, a slim fitting level with a ceiling, a shelf or a cove. The outside lamp has a body closed against rain.

### Is the lighting circuit switched off?

Yes. We open the breaker for that lighting circuit before any joint is made, and we leave it open. A breaker is the switch for one circuit on the consumer unit, the board at the incoming supply. Lamps already on that breaker go dark. Sockets stay on. Lamps fed from other breakers stay on.

### How does the cable reach the lamp?

The cable travels from the consumer unit to the lamp through the floor void, between the joists, or in conduit on the surface. That path is the cable route. If the boards above will come up, the cable crosses in that gap. A lath and plaster ceiling, plaster pressed onto thin timber strips, is drilled only after each joist is found. On a solid slab the cable uses a channel already formed, or conduit fixed on the surface. Conduit is a round tube around the cable. We open the ceiling only at the lamp.

### What is connected at the lamp?

We land live, neutral and earth at the lamp, and we land them again in the recess behind the control. Live is the conductor that brings current. Neutral is the conductor that returns it. Earth is the conductor that carries current away in a fault. A toggle makes the lamp fully bright or fully dark. A dimmer module, the part that sets brightness, goes in when the lamp should fade. A metal plate waits until earth is already in the cable. If an outside lamp would overload the indoor lighting circuit, we add a spur through a residual current device. A spur is a short branch. A residual current device opens when current leaks away.

### Which readings come before the lamps light?

We take three readings while the breaker is still open. Continuity follows each conductor from the lamp back to the consumer unit and shows it is unbroken. Polarity shows live and neutral have not swapped at the terminals. Earth fault loop impedance shows a fault current is strong enough to open the breaker. Only then do we close the breaker. We operate each toggle and each dimmer after that.

## Questions about new lamps


### Do you carry out lighting installation?

Yes. Bello Electrics Ltd fits new lamps indoors and outdoors, together with the switch or dimmer that runs them. The company is NICEIC accredited, with public liability insurance and indemnity insurance on the work.

### Do you fit lights across SW15?

Yes. Lighting installation covers Putney High Street, Putney Heath and West Hill, in homes and in commercial rooms. One lamp can be fitted, or several lamps fed from one circuit.

### How soon can new lamps be booked?

Book Now reserves the lighting visit. We answer the telephone day and night. The lamps go in on the visit that reservation creates.

### Have you fitted lamps, dimmers and garden lights?

Yes. Finished lamps include a long LED set into a commercial ceiling of timber slats, warm cove light and downlights on a ceiling of sunken panels, strips under fitted shelves, and ground lamps aimed up a trunk and the plants by a fence of timber slats. They also include small lamps in a herringbone timber floor beside a wall panel, modules for six dimmers in one recess behind a metal clad plate, and a strip that traces the fan over a shower.

### What happens after the lighting is booked?

We mark each lamp place, then open the breaker for that circuit. We join the lamps and the controls while the breaker stays open. We close the breaker after the readings, and we operate each control.

## Other services in Putney

- [Electrician in Putney](https://belloelectricsltd.co.uk/electrician-putney): Electrical work in Putney from Bello Electrics Ltd includes condition reports, new fuse boxes, rewiring, lighting, smoke alarms, chargers and fault repairs.
- [Lighting installation (all areas)](https://belloelectricsltd.co.uk/services/lighting-installation): Lighting installation across Battersea, Clapham, Chelsea, Fulham, and Wandsworth by Bello Electrics Ltd. Neat fittings and modern switching.
- [PAT testing in Putney](https://belloelectricsltd.co.uk/electrician-putney/pat-testing)
- [EV charger installation in Putney](https://belloelectricsltd.co.uk/electrician-putney/ev-charger-installation)
- [EICR and electrical surveys in Putney](https://belloelectricsltd.co.uk/electrician-putney/eicr)
- [Fire and smoke alarms in Putney](https://belloelectricsltd.co.uk/electrician-putney/fire-and-smoke-alarms)
- [Electrical faults and maintenance in Putney](https://belloelectricsltd.co.uk/electrician-putney/electrical-fault-finding)
- [House rewiring in Putney](https://belloelectricsltd.co.uk/electrician-putney/house-rewiring)

## Business facts
- Service area: Collier's Wood, Tooting, Streatham, Balham, Wandsworth, Putney, Battersea, Clapham, Oval, Brixton, Vauxhall, Pimlico, Chelsea, South Kensington, Mayfair, Fulham, Purley, Carshalton, Sutton, Kensington, North Kensington, Knightsbridge, Hammersmith and Fulham, Belgravia, Earl's Court, West Brompton, West Kensington, Croydon, Earlsfield, Wandsworth Common, Clapham Junction, Tooting Bec, Nine Elms, Stockwell, Parsons Green, Sands End
- Calls: Calls answered 24/7
- Phone: +447455213345
- Email: info@belloelectricsltd.co.uk
- Address: Mitcham CR4 1JU
- Insurance: Professional indemnity £1M, Public liability £5M
- Qualifications: BS7671; Testing and inspection; Initial verification; EV charging; PAT Test

## Book Now
- [Book Now](https://belloelectricsltd.co.uk/#chat): Send the job details and request a quote from Bello Electrics Ltd.

## Sitemap
- [Full sitemap](https://belloelectricsltd.co.uk/sitemap.md): Complete machine-readable page directory.
