EICR testing and electrical surveys from Bello Electrics Ltd provide landlords, buyers and homeowners with clear inspection certificates, with calls answered any time, day or night.

## EICR and electrical surveys starting prices

Starting prices reflect a standard domestic electrical inspection based on the number of circuits present in your consumer unit.
- EICR: from £160
- Landlord electrical certificate: Price on request
- Pre-purchase electrical survey: Price on request
- Inspection charges cover the visual check and electrical testing of installed wiring circuits.
- Remedial work, replacement parts, and investigative repairs for identified faults are quoted separately.
- Access to consumer units and all socket outlets must be clear before testing begins.

### Within the agreed scope
- Visual inspection of the main intake equipment, meter tails, and consumer unit
- Testing earthing arrangements and protective bonding conductors
- Testing fixed circuit wiring including lighting, power sockets, and cooker points
- Checking the correct operation of residual current devices and circuit breakers
- Delivery of a complete electrical installation condition report detailing observed observations

### Confirm separately
- Immediate repair of faults or code defects discovered during the survey
- Testing portable appliances, plugged-in white goods, or freestanding equipment
- Lifting fixed flooring or opening sealed wall cavities to trace buried runs
- Repairing damaged plaster or decorative surfaces following access checks

## EICR and electrical surveys explained

An electrical installation condition report checks whether the fixed wiring in your property remains safe for continued use.
- **Landlord safety duties:** Private landlords must have the electrical installations in their properties inspected and tested by a qualified person at least every five years, supplying a copy of the report to tenants.
- **Homebuyers and property transactions:** A pre-purchase electrical survey checks fixed wiring before you exchange contracts, identifying aged consumer units or outdated cabling in period properties across Wandsworth, Chelsea, and Clapham.
- **Routine homeowner checks:** Homeowners commission testing to uncover hidden deterioration behind walls, check earth bonding, and confirm whether circuits can safely support modern domestic appliances.

## What happens on the day

Testing involves turning off the electrical supply to individual circuits while instruments take measurements.
- **Power interruptions:** The mains electricity will be isolated for periods during the visit. We recommend shutting down sensitive electronic devices, home servers, and desktop computers beforehand.
- **Access to electrical fittings:** Please ensure clear access to the fuse board, electricity meter, and representative sockets and switches throughout the property, including areas behind furniture.
- **Consumer unit location:** In purpose-built flats or period conversions across Battersea and Fulham, consumer units may be positioned in communal cupboards or high on hallway walls. Please confirm keys or access routes are ready.

## How booking works
1. **Tell us about the job:** Tap Book Now and describe the work in the chat. Photos help.
2. **Get your price:** You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
3. **Choose your visit:** Give your address and when you are free, and the visit is arranged.

## EICR and electrical surveys questions

### What is the difference between an EICR and an electrical survey?

An electrical installation condition report, or EICR, is the formal technical document produced following full inspection and testing of the fixed wiring. Homebuyers often refer to this process as a pre-purchase electrical survey, but both terms describe the same in-depth assessment of the property's circuits and distribution equipment.

### How long does an electrical inspection take?

A typical domestic inspection takes between two and four hours, depending on the size of the home, the number of circuits wired into the consumer unit, and how easily points can be accessed. Larger properties or installations with multiple sub-boards require additional time to complete all instrument tests.

### What happens if an installation receives an unsatisfactory result?

An unsatisfactory report means the testing identified issues categorised as either dangerous or potentially dangerous. Landlords have a statutory duty to carry out the required investigative or remedial work within twenty-eight days, or sooner if specified in the report, to achieve compliance.

### Do you need to lift floorboards during the survey?

Standard condition reporting is non-destructive. We inspect accessible fittings, open selected sockets, light switches, and the consumer unit, and test cabling using calibrated instruments. Floorboards are not lifted and walls are not opened unless specific arrangements are made in advance.

### How often should a homeowner book an electrical survey?

For owner-occupied domestic homes, an inspection is generally recommended every ten years, or upon a change of occupancy. If an installation is older or has experienced noticeable additions over time, checking circuits every five years helps maintain safety.

## Business facts
- Service area: Colliers Wood, Tooting, Streatham, Balham, Wandsworth, Putney, Battersea, Clapham, Oval, Brixton, Vauxhall, Pimlico, Chelsea, South Kensington, Mayfaair, Fulham
- Hours: Calls answered 24/7
- Phone: +447455213345
- Email: info@belloelectricsltd.co.uk
- Insurance: Public liability £5M, Professional indemnity £1M
- Qualifications: BS7671; Testing and inspection; Initial verification; EV charging; PAT Test